You can use IPMI commands to test that the node is properly responding to power requests. Example:
[stack@director ~]$ ipmitool -I lanplus -U admin -P password -H 192.168.1.111 chassis status [stack@director ~]$ ipmitool -I lanplus -U admin -P password -H 192.168.1.112 power status [stack@director ~]$ ipmitool -I lanplus -U admin -P password -H 192.168.1.113 power off [stack@director ~]$ ipmitool -I lanplus -U admin -P password -H 192.168.1.114 power on
introspect again.
[stack@director ~]$ ironic node-set-maintenance <UUID> TRUE [stack@director ~]$ ironic node-delete <UUID>
To change an ironic node state to force provisioning or cleanup:
[stack@director ~]$ ironic node-set-provision-state <UUID> active|delete|rebuild|inspect|provide|manage
To clear an error status from an ironic node:
[stack@director ~]$ ironic node-set-provision-state <UUID> delete
Do not do a bulk this time, do only the one node that failed.
[stack@director ~]$ openstack baremetal introspection <UUID> start